e-Mail: contact@zena.net |
|
Series
150 -- Series 200 -- Series 250
|
|||||
Power Output @ 100% Duty Cycle | Series
150 --> 150 amps. (VIEW
Output Curve)
Series 200 --> 200 amps. (VIEW Output Curve) Series 250*--> 250 amps. (View Output Curve) |
(mounted
per factory recommendations, turning in recommended direction, with no obstruction
to flow of cooling air)
Series 250 requires ZENA model ER350 external full-wave rectifier assembly |
|||
Minimum Drive Engine Power / Torque Requirements | Series
150 --> 11 hp (Gas), 8 hp (Diesel)
Series 200 --> 16 hp (Gas), 11 hp (Diesel) Series 250 --> 22 hp (Gas), 14 hp (Diesel |
Series
150 --> (View
Torque Curve)
Series 200 --> (View Torque Curve) Series 250 --> (View Torque Curve) |
|||
Case Dimensions | Series
150 -- 6.5" W x 8.5" H x 7" D Series 150B -- 6.5" W x 8.5" H x 9" D Series 200 -- 6.5" W x 9.5" H x 10" D Series 250 -- 7.5" W x 9.5" H x 9" D |
(Clear space clearance requirement -- including pulley, terminals, and mounting lugs) | |||
Typical Voltage Output @ Full Power w/Arc Established | 20-26V Ultra High Frequency DC | (Typically 18,000-21,000 pulses/controlled wave form transitions per second) | |||
Typical Voltage Output @ Full Power w/NO Arc Established | 68-74V Ultra High Frequency DC | (Typically 18,000-21,000 pulses/controlled wave form transitions per second) | |||
Min. Power Generator Shaft Speed for Maximum Output Power | Approximately 6,500 RPM | (Higher shaft speeds — up to approximately 16,000 rpm - have no detrimental effect on welding performance) | |||
Typical Min. Engine Speed for Max. Output Power | Approximately 2,400 RPM | (Assumes typical engine drive pulley to Power Generator pulley ratio of approximately 2.5:1) | |||
Direction of Rotation | Series
150 -- Clockwise Rotation Series 150B -- Bi-directional Rotation (Clockwise Typical -- Hi-Efficiency Clockwise Option Available) Series 200 -- Bi-directional Rotation (Clockwise Typical) Series 250 -- Bi-directional Rotation (Clockwise Typical) |
Series 150B, 200 & 250 NOTE: Optionally, for high vibration applications, an anaerobic stud/bearing fixing adhesive can also be used to insure secure and continuous, Drive Pulley to Cooling Fan and Drive Pulley to Power Generator Drive Shaft Nut contact. |
|||
System Cooling | High Efficiency Forced Air | ||||
Expected Minimum Time Before Moving Component Failure | 50,000 hours (rotating - welding load) | NOTE:
50,000 hours = 2,083 twenty-four hour days (5.7 years of continuous operation) |
|||
Periodic Maintenance Requirement | None | NOTE:
Cleaning (with water and/or compressed air) may be required if operating in very dirty conditions, or if chemical contamination occurs. |
|||
DC Power Required (When Welding) | 12 volts -- 7 amps. maximum | (2 to 4 amps at average welding power settings in 12V electrical system) | |||
DC Power Required (When NOT Welding) | 12 volts -- .05 amps. | ||||
Control Circuit Protection | Internal Fuses (2) | (2 amp & 10 amp) | |||
Welding Controls | Internal,
Solid State OR External, Solid State |
(Built
into electrode holder/welding cable assembly) (Various panel mount type control options) |
|||
Accessory Control Circuits |
External Device Control Outputs --> Two Standard (more control outputs can be provided) |
Control
outputs to control up to 3 separate ASC Series speed controls, and for up to 6 separate
WC.12S Slave Power Control Modules. (additional control outputs can be provided as an extra cost option) |
|||
Welding Rod Sizes | Series
150 --- 1/16" to 1/8" (All) to 5/32" (Some)
|
||||
Welding Rod Compatibility | ALL
Types, AC or DC, including
specialty rods: Mild Steel, Low Hydrogen Steel, Stainless, Aluminum, Nickel, Nomacast, Brazing, Hard Surfacing --- AND Cutting Rods |
||||
|
You have no risk if you order on-line, all units are sold with a 60-day money back guarantee of satisfaction.
US & Foreign Patents Pending © Copyright 1998,1999, 2000, 2001 by ZENA, Incorporated. All rights reserved. [an error occurred while processing this directive] |