e-Mail: contact@zena.net |
High Amp Alternator Specifications |
||||||||||||||||||||||||||
|
|||||
Charging Power Output in 12V Electrical System (13.8V - 14.5VDC nominal) | Series
150 --> 150 amps. (View
Output Curve)
Series 200 --> 200 amps. (View Output Curve) Series 250*--> 250 amps. (View Output Curve) |
(mounted
per recommendations with no obstruction to flow of cooling air) Series 250 requires ZENA model ER350 external full-wave rectifier assembly |
|||
Charging Power Output in 24V Electrical System (27.6V - 29VDC nominal) | Series
150 --> 80 amps. (View
Output Curve)
Series 200 --> 125 amps. (View Output Curve) Series 250 --> 140 amps. (View Output Curve) |
(mounted
per recommendations with no obstruction to flow of cooling air) Series 250 requires ZENA model ER350 external full-wave rectifier assembly |
|||
Minimum Drive Engine Power / Torque Requirements | Series
150 --> 11 hp (Gas), 8 hp (Diesel)
Series 200 --> 16 hp (Gas), 11 hp (Diesel) Series 250 --> 22 hp (Gas), 14 hp (Diesel |
Series
150 --> (View
Torque Curve)
Series 200 --> (View Torque Curve) Series 250 --> (View Torque Curve) |
|||
Case Dimensions | Series
150 -- 6.5" W x 8.5" H x 7" D (See Series 150 Illustration) Series 150B -- 6.5" W x 8.5" H x 9" D (See Series 150B Illustration) Series 200 -- 6.5" W x 9.5" H x 10" D (See Series 200 Illustration) Series 250 -- 7.5" W x 9.5" H x 9" D (See Series 250 Illustration) Series ER350 External Rectifier -- 6" W x 4.5" H x 9" D |
(Clear space clearance requirement -- including pulley, terminals, and mounting lugs) | |||
Minimum Shaft Speed for Maximum Output Power | Approximately 6,500 RPM | (higher shaft speeds – up to approximately 16,000 rpm - have no detrimental effect on performance) | |||
Minimum Shaft Speed for Minimum Output Power | Approximately 1,500 RPM | ||||
Direction of Rotation | Series
150 -- Clockwise Rotation Series 150B -- Bi-directional Rotation (Clockwise Typical -- Hi-Efficiency Clockwise Option Available) Series 200 -- Bi-directional Rotation (Clockwise Typical) Series 250 -- Bi-directional Rotation (Clockwise Typical) |
Series 150B, 200 & 250 NOTE: Optionally, for high vibration applications, an anaerobic stud/bearing fixing adhesive can also be used to insure secure and continuous, Drive Pulley to Cooling Fan and Drive Pulley to Power Generator Drive Shaft Nut contact. |
|||
Generator Cooling | High Efficiency Forced Air, External Fan | (rear to front air flow) | |||
Expected Minimum Time Before Moving Component Failure | 40,000 hours | ||||
Periodic Maintenance Requirement | None, other than cleaning, as necessary to remove oils, chemicals, and/or corrosive materials in cases where maintaining a clean operating environment is not possible. | NOTE: Cleaning (with fresh water and/or compressed air) may be required if operating in very dirty conditions, or if chemical contamination occurs. |
|||
Rotor
Current Required (for Full Power Charging) |
12 volts
-- 7 amps. maximum 24 volts -- 4 amps. maximum |
||||
Voltage Regulator Type Required |
ANY A Circuit, or B Circuit (or type N, or type P) high current solid state external voltage regulator OR a ZENA model WC.VR Universal Voltage/Current Regulator used in combination with one, or more, ZENA WC.12 Power Control Modules OR a ZENA model WC.VR2 Universal Voltage/Current Regulator (w/ Over Temperature Sensing) used in combination with one, or more, ZENA WC.12 Power Control Modules OR a custom designed OEM control system conforming to guidelines provided by ZENA, Inc. |
NOTE: In applications where long term high current demands exist, and/or where very large battery banks are in place, and/or where batteries with very low battery impedance loads are employed, active protection methods should be employed. Such devices include regulators which limit maximum charging current and/or sophisticated voltage regulators which monitor and regulate alternator temperature (such as our WC.VR2), output/charging lead temperature, and battery temperature should be employed. |
|||
Tachometer Signal Output (Available as an Extra Cost Factory Option) |
150
Series --> Available (+US$50) 200 Series --> Available (+US$60) 250 Series --> Available (+US$65) |
NOTE: Tachometer Output can be in the form of EITHER an AC Stator Tap, a rectified + Stator Tap, or a rectified - Stator Tap. Signal output is an insulated #10 terminal post installed on the rear of the generator case (un-fused). Check with your tachometer manufacturer to determine the sort of signal expected for proper operation. |
|||
Suggested Retail Prices (Shipping cost NOT included) |
SR150.12
--> US$365 SR150.24 --> US$435 SR150B.12 --> US$465 SR150B.24 --> US$535 SR200.12 --> US$675 SR200.24 --> US$740 SR250.12 & ER350 --> US$1,105 SR250.24 & ER350 --> US$1,225 |
NOTE: Both 12VDC and 24VDC output models are available with either 12V OR 24V rotor assemblies (an extra cost option). This allows, for example, the use of ZENA welders in vehicles with 24V electrical systems OR the mounting of 24V charging systems on engines with 12V electrical systems. |
|||
|
You have no risk if you order on-line, all units are sold with a 60-day money back guarantee of satisfaction.